The Lysis LSA Series Plug-and-Measure Linearizer/Flow Computer corrects the frequency output of Turbine flowmeters for the effects of temperature and viscosity. It also linearizes and scales the Flow and Temperature outputs in a variety of formats including CAN.
The Lysis Flow Transmitters combine in a single instrument Linearization, UCV or UVCpro Temperature compensation, signal conditioning, used-selectable outputs and advanced communication options. The user-friendly FlowHow+ programming software allows easy programming of flow calibration and fluid properties data as well as linearization and scaling of Flow and Temperature outputs.
Lysis’ smart transmitter is available in two versions:
- LSA-ST-07-V1-07-07-00 Rectangular housing
- LSA-ST-08-V1-07-08-00 Rectangular housing, CAN
Advantages LYSIS LSA
- Open software architecture with user-defined password protection. ALL scaling and programming options are accessible by the end user
- Never a charge for programming. Reprogramming is included in the price of the flowmeter calibration for the life of the instrument
- Compatible with every flowmeter that is equipped with a Lysis SMART Pickoff (Plug-and-Measure)
- Upon connection with ANY TrigasDM SMART Pickoff equipped flowmeter, Lysis gains access to the preprogrammed calibration and fluid properties data and all signals from the SMART Pickoff
- User-friendly FlowHow+ programming software with run-live mode for easy programming and troubleshooting of all available functions and features
- Available in a variety of housings and connector configurations
- Mass and Volumetric flow capability
- Linearized Flow and Temperature outputs
- UVC and UVCpro correction capability for the effects of Temperature and
Viscosity - Sophisticated proprietary interpolation algorithms for Flow, Temperature, Density
and Viscosity data
Input signal:
ST – SMART-Pickoff with temperature sensor, 5 pin
Output Signal Options
05 – 0-10V flow rate + 0-10V temperature + raw frequency + TTL pulses | 07 – 0-10 V flow rate + 0-10 V temperature | 08 – CAN
Supply Voltage
V1 – 6-36 VDC
Housing options
07 – Lysis Square housing IP68